ingrPktsΒΆ

Name Type
Description
floodAvg integer
Ingress flood average packets.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
floodCum integer
Ingress flood cumulative packets.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
floodMax integer
Ingress flood maximum packets.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
floodMin integer
Ingress flood minimum packets.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
floodPer integer
Ingress flood packets per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
floodRate float
Ingress flood packets rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
multicastAvg integer
Ingress multicast packet average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
multicastCum integer
Ingress multicast cumulative packets.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
multicastMax integer
Ingress multicast packets maximum read.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
multicastMin integer
Ingress multicast packets minimum read.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
multicastPer integer
Ingress multicast packets per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
multicastRate float
Ingress multicast packet rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
unicastAvg integer
Ingress unicast average packets.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
unicastCum integer
Ingress unicast packets cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
unicastMax integer
Ingress unicast packets maximum read.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
unicastMin integer
Ingress unicast packets minimum read.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
unicastPer integer
Ingress unicast packets per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
unicastRate float
Ingress unicast packet rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
intervalStart time
Interval start time.
Timestamp of when interval started.
intervalEnd time
Interval end time.
Timestamp of when interval ended.