egrBytesΒΆ

Name Type
Description
floodavg integer
Egress flood bytes average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
floodCum integer
Egress flood bytes cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
floodMax integer
Egress flood bytes maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
floodMin integer
Egress flood bytes minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
floodPer integer
Egress flood bytes total in period
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
multicastAvg integer
Egress multicast bytes average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
multicastCum integer
Egress multicast bytes cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
multicastMax integer
Egress multicast bytes maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
multicastMin integer
Egress multicast bytes minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
multicastPer integer
Egress multicast bytes per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
floodRate float
Egress flood byte rate
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
multicastRate float
Egress multicast byte rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
multicastRateAvg float
Egress multicast byte rate average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval. This value is in bytes per second.
multicastRateMax float
Egress multicast byte rate maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval. This value is in bytes per second.
multicastRateMin float
Egress multicast byte rate minimum
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval. This value is in bytes per second.
intervalStart time
Interval start time.
Timestamp of when interval started.
intervalEnd time
Interval end time.
Timestamp of when interval ended.