egrTotalΒΆ

Name Type
Description
bytesAvg integer
Egress bytes average
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
bytesCum integer
Egress bytes cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
bytesMax integer
Egress bytes maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
bytesMin integer
Egress bytes minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
bytesPer integer
Egress bytes per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
bytesRate float
Egress byte rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
bytesRateAvg float
Egress byte rate average.
This is the average value read by the counter
during the collection interval. This value resets
to 0 at the beginning of each interval and is in
bytes per second.
bytesRateMax float
Egress byte rate maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval. It is in bytes per second.
bytesRateMin float
Egress byte rate minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval. It is measured in bytes per second.
pktsAvg integer
Egress packets average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval.
pktsCum integer
Egress packets cumulative.
The total sum of the values read. Note that this
value continues through each interval without
resetting to zero.
pktsMax integer
Egress packets maximum value read.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval.
pktsMin integer
Egress packets minimum value read.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval.
pktsPer integer
Egres packets per interval.
The total sum of the values read during the
collection interval. Note that this value resets
to 0 at the beginning of each interval.
pktsRate float
Egress packet rate.
This is the rate of the counter during the
collection interval. The rate is calculated by
dividing the periodic value by the length of the
collection interval in seconds. Note that this
value resets to 0 at the beginning of each
interval.
pktsRateAvg float
Egress packet rate average.
This is the average value read by the counter
during the collection interval. Note that this
value resets to 0 at the beginning of each
interval. It is measured in packets per second.
pktsRateMax float
Egress packet rate maximum.
This is the largest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
larger than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 4, the previous value is
overwritten with 4. If the third reading is
smaller than 4, the value remains at 4. Note that
this value resets to 0 at the beginning of each
interval. It is measured in packets per second.
pktsRateMin float
Egress packet rate minimum.
This is the smallest value read by the counter
during the collection interval. This value is
only overwritten if the most current value is
smaller than the previous value. For example, if
the value of the first reading is 3 and the value
of the second reading is 2, the previous value is
overwritten with 2. If the third reading is
larger than 2, the value remains at 2. Note that
this value resets to 0 at the beginning of each
interval. It is measured in packets per second.
intervalStart time
Interval start time.
Timestamp of when interval started.
intervalEnd time
Interval end time.
Timestamp of when interval ended.