egrDropPktsΒΆ

Name Type
Description
afdWredAvg integer
Egress packets dropped due to AFD or WRED.
This is a count of the packets dropped due to whichever active
queue managment mechanism is running in the switch, either AFD
or WRED. This is the average value read by the counter during
the collection interval. Note that this value resets to 0 at the
beginning of each interval.
afdWredCum integer
Egress packets dropped cumulative due to AFD or WRED.
The total sum of the values read. Note that this value continues
through each interval without resetting to zero.
afdWredMax integer
Egress packets dropped by AFD or WRED maximum value read.
This is the largest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is larger than the previous value. For example, if
the value of the first reading is 3 and the value of the second
reading is 4, the previous value is overwritten with 4. If the
third reading is smaller than 4, the value remains at 4. Note
that this value resets to 0 at the beginning of each interval.
afdWredMin integer
Egress packets dropped by AFD or WRED minimum value read.
This is the smallest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is smaller than the previous value. For example,
if the value of the first reading is 3 and the value of the
second reading is 2, the previous value is overwritten with 2.
If the third reading is larger than 2, the value remains at 2.
Note that this value resets to 0 at the beginning of each
interval.
afdWredPer integer
Egress packets dropped by AFD or WRED per interval.
The total sum of the values read during the collection interval.
Note that this value resets to 0 at the beginning of each
interval.
afdWredRate float
Egress packets dropped by AFD or WRED rate.
This is the rate of the counter during the collection interval.
The rate is calculated by dividing the periodic value by the
length of the collection interval in seconds. Note that this
value resets to 0 at the beginning of each interval.
bufferAvg integer
Egress packets dropped due to buffer full.
This is the average value read by the counter during the
collection interval. Note that this value resets to 0 at the
beginning of each interval.
bufferCum integer
Egress packets dropped cumulative due to buffer full.
The total sum of the values read. Note that this value continues
through each interval without resetting to zero.
bufferMax integer
Egress packets dropped due to buffer full maximum read.
This is the largest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is larger than the previous value. For example, if
the value of the first reading is 3 and the value of the second
reading is 4, the previous value is overwritten with 4. If the
third reading is smaller than 4, the value remains at 4. Note
that this value resets to 0 at the beginning of each interval.
bufferMin integer
Egress packets dropped due to buffer full minimum read.
This is the smallest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is smaller than the previous value. For example,
if the value of the first reading is 3 and the value of the
second reading is 2, the previous value is overwritten with 2.
If the third reading is larger than 2, the value remains at 2.
Note that this value resets to 0 at the beginning of each
interval.
bufferPer integer
Egress packets dropped due to buffer full per interval.
The total sum of the values read during the collection interval.
Note that this value resets to 0 at the beginning of each
interval.
bufferRate float
Egress packets dropped due to buffer full rate.
This is the rate of the counter during the collection interval.
The rate is calculated by dividing the periodic value by the
length of the collection interval in seconds. Note that this
value resets to 0 at the beginning of each interval.
errorAvg integer
Egress packets dropped due to error.
This is the average value read by the counter during the
collection interval. Note that this value resets to 0 at the
beginning of each interval.
errorCum integer
Egress packets dropped cumulative due to error.
The total sum of the values read. Note that this value continues
through each interval without resetting to zero.
errorMax integer
Egress packets dropped due to error maximum read.
This is the largest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is larger than the previous value. For example, if
the value of the first reading is 3 and the value of the second
reading is 4, the previous value is overwritten with 4. If the
third reading is smaller than 4, the value remains at 4. Note
that this value resets to 0 at the beginning of each interval.
errorMin integer
Egress packets dropped due to error minimum read.
This is the smallest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is smaller than the previous value. For example,
if the value of the first reading is 3 and the value of the
second reading is 2, the previous value is overwritten with 2.
If the third reading is larger than 2, the value remains at 2.
Note that this value resets to 0 at the beginning of each
interval.
errorPer integer
Egress packets dropped due to error per interval.
The total sum of the values read during the collection interval.
Note that this value resets to 0 at the beginning of each
interval.
errorRate float
Egress packets dropped due to error rate.
This is the rate of the counter during the collection interval.
The rate is calculated by dividing the periodic value by the
length of the collection interval in seconds. Note that this
value resets to 0 at the beginning of each interval.
intervalStart time
Interval start time.
Timestamp of when interval started.
intervalEnd time
Interval end time.
Timestamp of when interval ended.