ingrDropPktsΒΆ

Name Type
Description
bufferAvg integer
Ingress packets dropped due to buffer full.
This is the average value read by the counter during the
collection interval. Note that this value resets to 0 at the
beginning of each interval.
bufferCum integer
Ingress packets dropped cumulative due to buffer full.
The total sum of the values read. Note that this value continues
through each interval without resetting to zero.
bufferMax integer
Ingress packets dropped due to buffer full max read.
This is the largest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is larger than the previous value. For example, if
the value of the first reading is 3 and the value of the second
reading is 4, the previous value is overwritten with 4. If the
third reading is smaller than 4, the value remains at 4. Note
that this value resets to 0 at the beginning of each interval.
bufferMin integer
Ingress packets dropped due to buffer full min read.
This is the smallest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is smaller than the previous value. For example,
if the value of the first reading is 3 and the value of the
second reading is 2, the previous value is overwritten with 2.
If the third reading is larger than 2, the value remains at 2.
Note that this value resets to 0 at the beginning of each
interval.
bufferPer integer
Ingress packets dropped due to buffer full per interval.
The total sum of the values read during the collection interval.
Note that this value resets to 0 at the beginning of each
interval.
bufferRate float
Ingress packets dropped due to buffer full rate.
This is the rate of the counter during the collection interval.
The rate is calculated by dividing the periodic value by the
length of the collection interval in seconds. Note that this
value resets to 0 at the beginning of each interval.
errorAvg integer
Ingress packets dropped due to error.
This is the average value read by the counter during the
collection interval. Note that this value resets to 0 at the
beginning of each interval.
errorCum integer
Ingress packets dropped cumulative due to error.
The total sum of the values read. Note that this value continues
through each interval without resetting to zero.
errorMax integer
Ingress packets dropped due to error max read.
This is the largest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is larger than the previous value. For example, if
the value of the first reading is 3 and the value of the second
reading is 4, the previous value is overwritten with 4. If the
third reading is smaller than 4, the value remains at 4. Note
that this value resets to 0 at the beginning of each interval.
errorMin integer
Ingress packets dropped due to error min read.
This is the smallest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is smaller than the previous value. For example,
if the value of the first reading is 3 and the value of the
second reading is 2, the previous value is overwritten with 2.
If the third reading is larger than 2, the value remains at 2.
Note that this value resets to 0 at the beginning of each
interval.
errorPer integer
Ingress packets dropped due to error per interval.
The total sum of the values read during the collection interval.
Note that this value resets to 0 at the beginning of each
interval.
errorRate float
Ingress packets dropped due to error rate.
This is the rate of the counter during the collection interval.
The rate is calculated by dividing the periodic value by the
length of the collection interval in seconds. Note that this
value resets to 0 at the beginning of each interval.
forwardingAvg integer
Ingress packets dropped due to forwarding.
This is the average value read by the counter during the
collection interval. Note that this value resets to 0 at the
beginning of each interval.
forwardingCum integer
Ingress packets dropped cumulative due to forwarding.
The total sum of the values read. Note that this value continues
through each interval without resetting to zero.
forwardingMax integer
Ingress packets dropped due to forwarding max read.
This is the largest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is larger than the previous value. For example, if
the value of the first reading is 3 and the value of the second
reading is 4, the previous value is overwritten with 4. If the
third reading is smaller than 4, the value remains at 4. Note
that this value resets to 0 at the beginning of each interval.
forwardingMin integer
Ingress packets dropped due to forwarding min read.
This is the smallest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is smaller than the previous value. For example,
if the value of the first reading is 3 and the value of the
second reading is 2, the previous value is overwritten with 2.
If the third reading is larger than 2, the value remains at 2.
Note that this value resets to 0 at the beginning of each
interval.
forwardingPer integer
Ingress packets dropped due to forwarding per interval.
The total sum of the values read during the collection interval.
Note that this value resets to 0 at the beginning of each
interval.
forwardingRate float
Ingress packets dropped due to forwarding rate.
This is the rate of the counter during the collection interval.
The rate is calculated by dividing the periodic value by the
length of the collection interval in seconds. Note that this
value resets to 0 at the beginning of each interval.
lbAvg integer
Ingress packets dropped due to load balancing.
This is the average value read by the counter during the
collection interval. Note that this value resets to 0 at the
beginning of each interval.
lbCum integer
Ingress packets dropped cumulative due to load balancing.
The total sum of the values read. Note that this value continues
through each interval without resetting to zero.
lbMax integer
Ingress packets dropped due to load balancing max read.
This is the largest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is larger than the previous value. For example, if
the value of the first reading is 3 and the value of the second
reading is 4, the previous value is overwritten with 4. If the
third reading is smaller than 4, the value remains at 4. Note
that this value resets to 0 at the beginning of each interval.
lbMin integer
Ingress packets dropped due to load balancing min read.
This is the smallest value read by the counter during the
collection interval. This value is only overwritten if the most
current value is smaller than the previous value. For example,
if the value of the first reading is 3 and the value of the
second reading is 2, the previous value is overwritten with 2.
If the third reading is larger than 2, the value remains at 2.
Note that this value resets to 0 at the beginning of each
interval.
lbPer integer
Ingress packets dropped due to load balancing per interval.
The total sum of the values read during the collection interval.
Note that this value resets to 0 at the beginning of each
interval.
lbRate float
Ingress packets dropped due to load balancing rate.
This is the rate of the counter during the collection interval.
The rate is calculated by dividing the periodic value by the
length of the collection interval in seconds. Note that this
value resets to 0 at the beginning of each interval.
intervalStart time
Interval start time.
Timestamp of when interval started.
intervalEnd time
Interval end time.
Timestamp of when interval ended.